ACOUSTICS
Tested as per BS EN ISO 354: 2003 for sound absorption, noise reduction and sound attenuation.
Maximum NRC achieved with Acoustic Black fleece – NRC 0.75
Maximum NRC achieved with Acoustic Black Fleece and Rockwool Insulation – NRC 1.00
Ceiling Systems
Linear
A strip ceiling system designed for internal and external application, with flush filler (rounded edge). Acoustics performance for internal system. Easy accessibility to ceiling void with access key tool. Offered in a wide range of sizes, colors & finishes.
Aluminum Alloy as per EN AW 3000 or 5000 series.
Zinc Plated Galvanized Steel G90 grade.
Aluminum: 0.5mm to 2.0mm.
Galvanized Steel: 0.45mm to 1.0mm
+ Custom thickness are available upon request
MODULE WIDTHS (mm): 100/150/200
STRIP WIDTHS (mm): 85/135/185
FILLER STRIP WIDTH: 15mm
PANEL DEPTH: 15mm
EDGE DETAIL:
RAM 111: Rounded
+ Custom sizes are available upon request
Plain
Perforated
Polyester Coating: (5µ (Back) +
20µ (Face)
Polyester Powder Coating: (70µ -80µ)
+ High Performance Coatings like PESDF, PVDF and POLYAMIDE are available upon request.
Acoustic Black Fleece is non-flammable and meets the standard DIN 4102 / B1. Classification A1 according to EN 13501-1.
Rockwool slabs conforming to ASTM C612 and equivalent BS 3958-5 are provided for acoustic insulation.
Tested as per BS EN ISO 354: 2003 for sound absorption, noise reduction and sound attenuation.
Maximum NRC achieved with Acoustic Black fleece – NRC 0.75
Maximum NRC achieved with Acoustic Black Fleece and Rockwool Insulation – NRC 1.00
Tested as per JIS Z 2801: 2000, which inhibits the growth of bacteria on the applied surface.
Achieved by the metal ceiling is LR – 0.85-0.96 tested as per ASTM E 1477.
Surface Spread of flame Class 1 tested as per BS 476: Part 7: 1997 “Non-Combustible” Material tested as per BS 476: Part4: 1970
Flame Spread and Smoke
Development Index tested as per ASTM E84 (Class 1 or A)